LD-100 POCT HbA1c Analyzer Real Time Detection Protable HbA1c Analyzer

Ask Latest Price
Video Channel
Brand Name :LABNOVATION
Model Number :LD-100
Certification :IFCC, NGSP, CE
Place of Origin :Shenzhen, China
MOQ :1
Price :Negotiation
Payment Terms :D/A, D/P, T/T
Supply Ability :100/Day
Delivery Time :10 work day
Packaging Details :Carton
Size :220mm*150mm*120mm
Net weight :≤5kg
Shelf Life :9 Months
Power connection :Detachable power supply cord
Working environment :Standard
Operating mode :Continuous
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

HbA1c Analyzer LD-100 POCT HbA1c Analyzer Protable Real-Time Detection HbA1c Analyzer

Intended Use

LD-100 POCT HbA1c Analyzer is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood. Which is a semi-automatic instrument used to analyze glycated hemoglobin and it's suitable for the detection of HbA1c in medical units at all levels.

Specifications

Model LD-100
Method Boronate Affinity
Operating Type 1-Step, fully automatic
Measurement Time Less than 3 minutes
Sample Type Whole blood
Sample Volume 4ul
Measurement Range HbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Data storage 7000
Operating Condition Temperature:15~35℃
Humidity:15~80%R.H
Storage Condition Analyzer:10-60℃; Test kit: 2~8℃
Voltage 12VDC-3.33A
Device category Fixed

LD-100 POCT HbA1c Analyzer Real Time Detection Protable HbA1c Analyzer

PRINCIPLE

  • Uses the (borate affinity) fluorescent immunoturbidimetry
  • Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
  • The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.
  • The total concentration of hemoglobin depends on the initial reduced fluorescence signal.
  • Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients.
  • The percentage of glycosylated hemoglobin in total hemoglobin can be determined.

Feature

  • One-step Operation, simple use process easy to test HbA1c
  • Protable, easy to carry
  • Fast tets speed, Real-time detection
  • Battery Integrated
  • Portable, Compact
  • Cv<3%, Excellent Correlation With HPLC
  • RFID For Batch Management
  • Color touch screen
  • External printer (Blue-tooth)
  • USB Port
  • LIS Support

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge

LD-100 POCT HbA1c Analyzer Real Time Detection Protable HbA1c Analyzer

Performance Parameters

  • Accuracy:The accuracy is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Result reporting unit:Glycated hemoglobin (HbA1c) is reported by default in IFCC units (mmol/mol) and NGSP units (%).
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, and the sample coefficient of variation (CV) of the test results is not more than 3%.
  • Appearance:The appearance of the instrument is neat and clean, and there is no obvious peeling, abrasion, disbonded coating and dirt on the surface coating; The nameplate and logo should be clear. All fasteners should not be loosened. Various adjusting elements can rotate flexibly and function normally. Readouts should be clear on the display screen.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficient r of the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the same normal sample is tested, and the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English; Abnormal alarm function.
  • Permission: The authority is the first-level authority, and the login authority is the first-level authority