Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample

Contact Now
Labnovation Technologies, Inc.
City:shenzhen
Country/Region:china
Contact Person:MissAimee li
Contact Now

Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample

Ask Latest Price
Video Channel
Brand Name :LABNOVATION
Model Number :LD-100
Certification :IFCC, NGSP, CE
Place of Origin :Shenzhen, China
MOQ :1
Price :Negotiation
Payment Terms :D/A, D/P, T/T
Supply Ability :100/Day
Delivery Time :15-20 working days
Packaging Details :Carton
Sample types :Whole blood
Test blood volume :4μL
Test Speed throughtput :20 samples per hour
Test time :<3 Minutes
Principle :Borate affinity fluorescent immunoturbidimetry
Data storage :7000 tests
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

LD-100 Analyzer POCT Best Performance IFCC&NGSP Certificated Battery Integrated One Step Use HbA1c Analyzer

Intended Use

Labnovation HbA1c Analyzer LD-100 POCT Analyzer is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood which is a semi-automatic instrument used to analyze glycated hemoglobin. LD-100 is small and light, it can be used to detect of HbA1c in medical units at all levels. Fually Automatic system can help the test half work with double results.

Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample

Specifications

Model LD-100
Sample Type Whole blood
Sample Volume 4ul
Test Time Less than 3 minutes
Data storage 7000
Method Fluorescent Immunoturbidimetry
Operating Type 1-Step Operation, Fully automatic system
Measurement Range HbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Operating Condition Temperature:15~35℃
Humidity:15~80%R.H
Storage Condition Analyzer:10-60℃; Test kit: 2~8℃
Voltage 12VDC-3.33A
Analytical wave-length 510nm and 580nm.
Certification NGSP, IFCC
Working Principles
HbA1c Analyzer uses the (borate affinity) fluorescent immunoturbidimetry. Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently. The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells. The total concentration of hemoglobin depends on the initial reduced fluorescence signal. Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients. The percentage of glycosylated hemoglobin in total hemoglobin can be determined.

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

Performance

  • Result reporting unit

Glycated hemoglobin (HbA1c) is reported by default in IFCC units (mmol/mol) and NGSP units (%).

  • Accuracy

The accuracy is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.

  • Precision

Samples with a concentration of 4.0%-6.5% are detected, and the sample coefficient of variation (CV) of the test results is not more than 3%.

  • Linearity

In the range of 4%-16% of HbA1c, the linear correlation coefficient r of the test results should be no less than 0.9900.

  • Stability

Within 8 hours after the instrument is turned on and stable, the same normal sample is tested, and POCT HbA1c Analyzer V1.0 2 the relative deviation of the test results is not more than ±3%.

Certificate

Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood SampleBattery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample

Attention

The HbA1c Analyzer meets the emission and immunity requirements specified in the relevant Section of GB/T 18268.26, as shown in the table below.

  • Users have the responsibility to ensure the electromagnetic compatibility environment of the equipment, so that the equipment can work properly.
  • It is recommended that the electromagnetic environment be evaluated before the equipment is used.